CL Solutions: World Leader in Aerobic Bioaugmentation
Plate Count Request FormPlace an orderContact CL Solutions
CL Solutions
Microbes for sustainable remediation of pollution
About CL Solutions Products Case Studies Master Contaminant List Material Safety Data Projects Summaries FAQs Home

Dry Cleaner located in Newport, Kentucky

Site Summary:

Dry cleaning solvent spills in a storage area lead to the contamination of soil and ground water on the property of a 50-year-old dry cleaner in the middle of a brownfield redevelopment. After the contaminated soil was excavated for off-site disposal to the most practical extent, residual perched ground water contamination impacted the redevelopment of the property.

The soil excavation was used as an infiltration gallery as part of a recirculating ground water recovery and treatment system. The ground water recirculation reduced contaminant concentrations, but the levels were still far above the levels required to achieve no further action status. CL-Out was added to the recirculating ground water, and the cleanup goals were achieved in less than two years and maintained through two years of post-treatment monitoring.

Geology and Hydrogeology

The site is on a fluvial terrace adjacent to the Ohio River. The shallow soils are clayey silts to eight feet deep. An interbedded sandy zone that formed the first water-bearing zone was encountered from 8 to 12 feet deep. Perched ground water occurred in the sandy zone at 12 feet below grade.

Ground Water Contamination

The size of ground water plume that resulted from the spills was estimated to be 3,500 square feet. The ground water contamination was mainly tetrachloroethene (PCE) with a maximum concentration of 11,000 µg/L prior to soil removal or ground water treatment. The daughter compounds, trichloroethylene (TCE) and dichloroethylene (DCE), were detected up to 17 and 12 µg/L, respectively. After three years of recirculation and flushing, the maximum PCE concentration was reduced to 2.3 µg/L and the daughter compounds were below detection limits.

Remediation Design

CL-Out bioaugmentation was implemented to supplement the flushing system. By adding CL-Out on two occasions over two years, the contaminant concentrations were reduced to below drinking water standards. During two years of post-treatment monitoring, the DCE concentrations rebounded to above the MCLs. CL-Out bioaugmentation was implemented again, and within three months, the contaminant levels were below drinking water standards and remained below drinking water standards for nine months.

Results

After post-closure monitoring verified the cleanup goals would be maintained, the Kentucky Department of Environmental Protection (KDEP) issued a “No Further Action” letter for the site.

The following chart shows the PCE contaminant trend in one of the key monitoring wells during the remediation and post closure monitoring.

The CL-Out cost during this remediation project was less than $10,000.

CL-Out Bioremediation Trend Graph for Dry Cleaner located in Newport, Kentucky

Please note that this graph is on a logarithmic scale.

Letter from Natural Resources and Environmental Protection Cabinet